●The device can cool the water temperature ranging from 7 to 35℃.
●The low cooling temperature can be customized as per customer's needs.
●The micro computer controls the system running and the temperature can be precise to ±1℃.
●The overload protection device is used for compressor and pump to prolong the service life.
●The multi protection device(antifreezing protection,high and low pressure protection and flow protection)ensures the system safety.
●The water tank is made from the stainless steel and has a heat insulation layer. Freezing pipelines have the insulation layer to improve refrigerating efficiency.
●Low speed and noise blower fan.
●The blower fan stops along with the compressor,thus effective electric energy saving.
Specifications:
Model | Refrigeration capacity | Compressor | Refrigerant | Water tank capacity (L) | Evaporator Type | Freeze water Pipe (Inch) | Freeze water flow rate | Fan motor | Sateguard | Power | Dimensions LxWxH(mm) | Weight (Kg) | ||||
KW | Kcal/h | Input power HP | Type | Filling quantity(Kg) | L/min | M3/h | Type | KW | ||||||||
SL-2AA | 5 | 5160 | 2 | R22 | 1.4 | 40 | Serpentine pipe type | 1" | 60 | 3.6 | Axial flow type blower fan | 0.13 | Protection of high & low pressure/ Compressor overload /Pump overload | AC3+N+PE 50/60Hz | 770x580x1115 | 200 |
SL-3AA | 10 | 7740 | 3 | 1.5 | 60 | 1" | 60 | 3.6 | 0.45 | 750x680x900 | 100 | |||||
SL-5AA | 15 | 12900 | 5 | 2.5 | 90 | 1" | 90 | 5.4 | 0.45 | 1100x680x1100 | 160 | |||||
SL-8AA | 20 | 20640 | 8 | 3.5 | 120 | 1" | 90 | 5.4 | 1.5 | 1480x840x1435 | 200 | |||||
SL-10AA | 30 | 25800 | 10 | 5 | 180 | 1.5" | 210 | 11 | 0.45x2 | 1450x790x1120 | 300 | |||||
SL-12AA | 40 | 30960 | 12 | 6 | 135 | 1.5" | 210 | 11 | 1.5 | 1640x940x1520 | 500 | |||||
SL-15AA | 45 | 38700 | 15 | 7.5 | 270 | 2" | 270 | 16 | 0.65x2 | 2200x1000x2100 | 700 | |||||
SL-20AA | 60 | 51600 | 20 | 10 | 350 | 2" | 315 | 16 | 0.65x2 | 2200x1320x2100 | 750 | |||||
SL-30AA | 90 | 77400 | 30 | 12 | - | Shell type | 3" | 16 | 0.65x4 | Protection of high & low pressure/ Compressor overload/Pump overload/ Antifreezing/ Flow rate | 2200x1320x2180 | 1400 | ||||
SL-40AA | 120 | 103200 | 40 | 18 | - | 3" | 23 | 0.65x4 | 2500x1200x2290 | 1600 | ||||||
SL-50AA | 150 | 129000 | 50 | 30 | - | 3" | 28 | 1.1x2 | 2200x2000x2180 | 2200 | ||||||
SL-60AA | 180 | 154800 | 60 | 35 | - | 4" | 33 | 1.8x4 | 3000x2200x2180 | 2400 |
Note:The working conditions for refrigeration:Freezing water inlet temperature is 12℃,and the outlet temperature is 7℃
Air side inlet (environmental temperature) is 35℃
※We reserve the right to change specifications without prior notice.
Structure:
NO. | NAME | NO. | NAME | NO. | NAME | |
1 | Under frame | 11 | No. 1 air deflector | 21 | No.2 decorative plate | |
2 | Side Panels | 12 | No.2 air deflector | 22 | No.3decorative plate | |
3 | Middle stand column | 13 | No.3 air deflector | 23 | Up back-side panel | |
4 | Water tank | 14 | No. 1 middle beam | 24 | Electrical Box | |
5 | Evaporator | 15 | No.2 middle beam | 25 | Movable Door | |
6 | Compressor | 16 | Fixed plate for heat exchange | 26 | Fixed Panel | |
7 | Pump | 17 | No. 1 decorative plate | 27 | Fixed panel for valve | |
8 | Front-left stand column | 18 | Front-right stand column | 28 | No. 1 mounting panel for column | |
9 | Back stand column | 19 | Fan panel | 29 | No.2 mounting panel for column | |
10 | Down back-side panel | 20 | Fan |
Diagram of installation: